Visualizing Forecast Performance vs Actuals

Visualizing Forecast Performance vs Actuals

A low RMSERMSERMSE might obscure periods where the forecast performs poorly, or it might not reveal systematic biases in the predictions. In addition, in certain cases, the profile is normalised to unity (i.e., scaled to bring the values into the range [0,1]). Several visualizations were used that might not be straightforward to understand and are therefore explained here, to be used as a reference. The findings underline the need to confirm, most importantly; future equipment loads, equipment and lighting (or occupancy) schedules, seasonality of use, and heating and cooling strategies of a building. Regulatory assumptions are those defined under the UK National Calculation Methodology, which pre-scribe the inputs for specific space types, in order to determine the minimum performance requirements of a building for Building Regulations (i.e., compliance modeling).

They help you understand what’s happening beneath those numbers and algorithms. Predicted vs Actual graphs and Residual plots are like friendly guides in your data science journey. The closer the points are to a straight line, the better the model’s predictions. Tell me about it in the comments section below, in case you have any additional questions.

Typical weekday and weekend day profiles of energy use were used to compare predicted and measured energy use and understand the hourly variation in energy use, profiles were created for a per year basis. Comparing typical weekday and weekend day for predicted and measured energy use proved to be helpful in determining typical hourly differences and identified if adjustments were necessary. In addition, typical lighting and equipment baseloads under compliance modeling are a gross under-prediction of actual baseloads measured in the four case study buildings. Discrepancies between predicted and measured energy use was mitigated through iterative adjustment of building energy model assumptions in four case study buildings.

Simplifications were applied both individually and combined to understand their individual and aggregated effect on energy use. To determine the impact of regulatory assumptions on energy use predictions and consequently the performance gap, typical NCM assumptions (i.e., simplifications) were applied to the manually calibrated base case models. As such, comparison of the NMBE and CV (RMSE) at different energy end-uses on a monthly basis were also made. At an hourly level however, both Office 17 and 71 show significant differences due to discrepancies between predicted and measured gas use. These limitations are a common issue with model calibration, however, most could be alleviated through rigorous and continuous commissioning, in addition to ensuring that a reliable metering strategy is in place.

As such, for performance modeling during design, it is essential to determine future use of spaces, potentially based on previous experience or data from existing buildings. Although environmental and system performance data was also analyzed to establish system settings and set-point temperatures, these variables are much more case study dependent. In addition, limitations are described that were likely to affect model calibration accuracy, typically due to a lack of information. Uncertainty analysis is typically accompanied by sensitivity analysis, which apportions the uncertainty of the model output to the input. For sampling, use is made of pyDOE (2017), an experimental design package for Python, with which Latin-hypercube designs were created. For each building, several thousand simulations were run in order to analyse the variance read more at centaur.reading.ac.uk in predictions.

Statistical calibration criteria, differences between predicted and measured energy use. All four case study buildings were calibrated within the ASHRAE criteria at a monthly level as shown in Table 2. For each model, parametric simulations created an input- and output space (i.e., samples of input parameters and predictions of energy use). Swipe card and Wi-Fi data were used to develop typical weekday and weekend day schedules, in particular Wi-Fi was effective at understanding the cumulative trend of people within the building, as shown in Figure 3. As shown in Figure 1, we have created a Base R scatterplot that shows predicted vs. actual values.

Maile et al. (2012) use data graphs to explain performance issues by comparing predicted and measured data. All building spaces were included in the model and zoning of the spaces was identified during walk-throughs of the buildings. According to ASHRAE (2013), this is a 5% monthly mean bias error on total yearly energy use and 10% for hourly mean bias error on yearly energy use. Whereas, the static performance gap is not well-understood, because performance modeling has not been common practice among practitioners, and where it is undertaken, predictions are often not validated. This paper quantifies the impact of underlying causes of the regulatory energy performance gap in four case study buildings. Post-occupancy evaluation of existing buildings is essential in understanding where and how energy is being used, how occupants behave, and the effectiveness of system strategies.

An overview is given of typical adjustments among the case study buildings, and more specific adjustments to adjust outliers. O&M manuals were to be reviewed to understand the design and intended operation of a building, which were subsequently validated through energy audits. For each building model, manual adjustments were made to bring the predicted energy use closer to measured energy use (i.e., manual calibration).

For Office 17, significant parameters are the lighting and equipment power densities, typical for office buildings that are naturally ventilated. For example, boiler efficiency is weakly correlated to total energy use, because of the small percentage of gas use out of total energy use, used solely for radiator heating within circulation spaces. The inputs and outputs were used to understand the sensitivity of the input parameters on the outputs. In Figure 8, energy end-uses for 3,000 simulations are compared with measured energy use (orange circles), displaying the uncertainty for each end-use. Then, the time series is again scaled to between 0 and 1, and a typical weekday and weekend day were calculated, as shown in Figure 7.